spacer gif spacer gif spacer gif spacer gif spacer gif
 QUICK SEARCH:   [advanced]


spacer gif
     Home     Help     Feedback     Subscriptions     Archive     Search     Table of Contents    


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by HALLY, A. D.
Right arrow Search for Related Content
PubMed
Right arrow Articles by HALLY, A. D.

Quarterly Journal of Microscopical Science, Vol s3-105, 503-517, Copyright © 1964 by Company of Biologists

A Counting Method for Measuring the Volumes of Tissue Components in Microscopical Sections

A. DOUGLAS HALLY M.D.1

1 Department of Anatomy, University of Glasgow, Scotland; Department of Anatomy, University of Newcastle upon Tyne, England

Several methods are available for estimating the relative volume of a tissue component from a study of tissue sections. These methods are all based on the fact that the mean relative area of a component in a series of random sections through a tissue is a consistent estimate of its relative volume in the whole tissue. Thus the problem is basically one of measuring area in a section, which can be done by the following simple counting method.

The method consists of placing a regular pattern of points in the form of a square lattice upon the section image, and counting the number of points over the section N, and over the component n

Relative area of component {doteqdot}n/N

The method also measures absolute ares, and where d is the distance between adjacent points,

absolute area of component {doteqdot}nd2

This capacity to measure absolute area means that the method is particularly suitable for determining a component which has a low relative volume.

The accuracy of the method is influenced by several factors including the size of the grid mesh, and the relative area, shape, and spatial arrangment of the component. With reasonable care the error will not be larger than that of a truly randon system of points, as expressed by the following:

relative standard error {doteqdot}{surd}(1-p)/{surd}n,

where p is the relative area of the component, and the relative standard error (R.S.E.) is S.E./relative area of component.

The method is equallyapplicable to either light or electron microscopy. A series of measurements on electron micrographs of rat cardiac muscle revealed a close agreement between the counting method and planimetry.

The method is rapid, simple and accurate, and requres no complex apparatus.







© The Company of Biologists Ltd 1964