spacer gif spacer gif spacer gif spacer gif spacer gif
 QUICK SEARCH:   [advanced]


spacer gif
     Home     Help     Feedback     Subscriptions     Archive     Search     Table of Contents    


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by WILLIAMS, P. L.
Right arrow Articles by WENDELL-SMITH, C. P.
Right arrow Search for Related Content
PubMed
Right arrow Articles by WILLIAMS, P. L.
Right arrow Articles by WENDELL-SMITH, C. P.

Quarterly Journal of Microscopical Science, Vol s3-101, 43-54, Copyright © 1960 by Company of Biologists

The Use of Fixed and Stained Sections in Quantitative Studies of Peripheral Nerve

P. L. WILLIAMS 1 and C. P. WENDELL-SMITH 1

1 Department of Anatomy, Guy's Hospital Medical School, London

A technique which has been widely used in quantitative studies of peripheral nerve involves fixation in Flemming's fluid, embedding in paraffin wax, and staining with haematoxylin. An appraisal of the size changes induced by a standardized form of this technique has been made. Observations have been confined to changes in the thickness and external diameter of the internodal compact myelin sheath of the non-fasciculated ncrvus gastrocnemius medialis or the adult rabbit.

For a comparison of external diameters, sections from adjacent parts of the chosen nerve were perpared (a) by the standardized Flemming-Wolter technique; (b) by the rapid freezing technique, previously shown to reproduce accurately the dimensions present in fresh teased unfixed nerve-fibres. There was no significant difference in distribution of external diameters between sections prepared in the two ways.

For a comparison of sheath thicknesses, a regression line of 2 X myelin sheath thickness on external diameter was derived from each type of preparation. As external diameter was not appreciably affected by processing, a direct comparison of these regression lines could be made. It was found that regardless of external diameter or original sheath thickness, processing caused a reduction of sheath thickness of some 20% as a result of increase in internal diameter. This latter increase ranged from about 50% to under 20% with increasing fibre size.

Single frozen sections were passed through the series of reagents used in the Flemming-Wolter technique and photographed after each of seven stages. The principal changes in sheath thickness occurred in the first and last stages of processing. External diameter was not appreciably affected whereas the internal margin of the sheath was extremely labile. Observations suggest that slight inconsistencies in technique may be accompanied by relatively gross errors when measurements are undertaken. All stages need careful standardization, the most important in this respect being fixation, differentiation, final dehydration, and photographic exposure.







© The Company of Biologists Ltd 1960