spacer gif spacer gif spacer gif spacer gif spacer gif
 QUICK SEARCH:   [advanced]


spacer gif
     Home     Help     Feedback     Subscriptions     Archive     Search     Table of Contents    


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Reichert, W. M.
Right arrow Articles by Truskey, G. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Reichert, W. M.
Right arrow Articles by Truskey, G. A.

Journal of Cell Science, Vol 96, Issue 2 219-230, Copyright © 1990 by Company of Biologists


JOURNAL ARTICLES

Total internal reflection fluorescence (TIRF) microscopy. I. Modelling cell contact region fluorescence

WM Reichert and GA Truskey
Department of Biomedical Engineering, Duke University, Durham, NC 27706.

Total Internal Reflection Fluorescence (TIRF) is a powerful technique for visualizing focal and close contacts between the cell and the surface. Practical application of TIRF has been hampered by the lack of straightforward methods to calculate separation distances. The characteristic matrix theory of thin dielectric films was used to develop simple exponential approximations for the fluorescence excited in the cell-substratum contact region during a TIRF experiment. Two types of fluorescence were examined: fluorescently labeled cell membranes, and a fluorescent water-soluble dye. By neglecting the refractive index of the cell membrane, the fluorescence excited in the cell membrane was modelled by a single exponential function while the fluorescence in the membrane/substratum water gap followed a weighted sum of two exponentials. The error associated with neglecting the cell membrane for an incident angle of 70 degrees never exceeded 2.5%, regardless of the cell-substratum separation distance. Comparisons of approximated fluorescence intensities to more exact solutions of the fluorescence integrals for the three-phase model indicated that the approximations are accurate to about 1% for membrane/substratum gap thicknesses of less than 50 nm if the cytoplasmic and water gap refractive indices are known. The intrinsic error of this model in the determination of membrane/substratum separations was 10% as long as the uncertainties in the water gap and cytoplasmic refractive indices were less than 1%.


This article has been cited by other articles:


Home page
J. Cell Sci.Home page
J Lee and K Jacobson
The composition and dynamics of cell-substratum adhesions in locomoting fish keratocytes
J. Cell Sci., January 11, 1997; 110(22): 2833 - 2844.
[Abstract] [PDF]


Home page
J. Cell Sci.Home page
G. A. Truskey, J. S. Burmeister, E. Grapa, and W. M. Reichert
Total internal reflection fluorescence microscopy (TIRFM). II. Topographical mapping of relative cell/substratum separation distances
J. Cell Sci., October 1, 1992; 103(2): 491 - 499.
[Abstract] [PDF]




© The Company of Biologists Ltd 1990