spacer gif spacer gif spacer gif spacer gif spacer gif
 QUICK SEARCH:   [advanced]


spacer gif
     Home     Help     Feedback     Subscriptions     Archive     Search     Table of Contents    


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by WESTRUM, L. E.
Right arrow Articles by LUND, R. D.
Right arrow Search for Related Content
PubMed
Right arrow Articles by WESTRUM, L. E.
Right arrow Articles by LUND, R. D.

Journal of Cell Science, Vol 1, 229-238, Copyright © 1966 by Company of Biologists

Submitted on November 27, 1965

Formalin Perfusion for Correlative Light- and Electron-Microscopical Studies of the Nervous System

L. E. WESTRUM 1 and R. D. LUND 2

1 Department of Anatomy, University College London Gower Street, London, W.C. I
2 Department of Anatomy, University College London, Gower Street, London, W.C. I

The formalin perfusion technique of Pease has been shown to be a satisfactory fixation method for both light and electron microscopy of the nervous system of rat and goldfish, so allowing correlative studies to be made on tissue from the same region of one brain.

Immediate post-osmication is not necessary for good ultrastructural preservation and even if itis delayed for 1 week, neuronal structure is adequate for all but detailed cytological work. Unosmicated tissue stained with uranyl acetate and lead citrate showed protein-like structures but not lipids, with membranes appearing as unstained bands. ‘Dark’ glial cells occurred near the surface of the cortex and could not be eliminated by prolonged fixation in situ. ‘Dark’ neurons were found rarely.

It is suggested that, with this method of fixation, any poor preservation of tissue in direct light- and electron-microscopical correlative studies is due to the subsequent processing rather than the initial fixation. Preliminary results on material stained by a new Golgi-Kopsch modification and by reduced silver methods and subsequently examined with the electron microscope suggest that such damage is not extensive.